back [<] |
|
| |
Weld timers |
|
| |
|
|
| |
Carregando
|
|
| |
The
ConAn with its partners
manufactures and markets
microprocessor- based
control of weld for any
type of resistance
welding machine.
It can be a simple weld
or one that requires
accuracy such as safety
parts, micro welding,
and welding with
non-ferrous materials.
Now with the new line WS
and iPAK, the most
modern and accurate in
current compensation,
proportional valve and
printer outputs with
optional Windows
software for
communications and
networking, and access
to edit weld program
parameters.
|
|
| |
|
|
| |
-
Weld timer EN-1001
-
| |

 |
Features:
• Constant current
• Spot Sequence
• Pulse Sequence
• Seam Sequence
• 50 programs
• 5 stepper's
• Output and process
errors
• Programming for
copying programs
• Multiple sequence
current
• Multiple weld
schedules
• Mode and successive
• Mode with or without
repetition
• Layout of front panel
• Extended functions
accessible via the front
panel |
|
|
|
|
| |
-
Weld timer WS700
-
| |

 |
Features:
• Modes of welding:
Simple spot, Repeat,
half cycle, Roll Spot
and Seam.
• Constant current with
best accuracy
• Up to 64 programs
• Integrated Programer
• Upslope and Downslope
• 16 inputs
• 8 outputs
• Current Monitoring
with High / Low limit
windows
•Proportional Valve
Control and Feedback
with High / Low Limit
windows
• Pressure Monitoring
• End of Sequence Output
• Retraction (3 modes)
• Spot Counter
• machine sequencer
software 250 lines (Basic)
• Programmable Output
• Contactor Output
• Low Force Approach
• Head lock Function
• Large backlit display
• RS232 port for printer
or PC connection |
|
|
|
|
| |
-
Weld timer WS2003
-
| |
|
The WS2003 is the direct
replacement of the
popular WS2000. The
timer unit fits in place
of the WS2000 using the
connections and power
supply available. The
WS2003 has a new
programming pendant with
a larger screen and
simplified keyboard.
Additional features such
as a programmable
logical sequencer,
Ethernet and fieldbus
cards are available for
new installations. Can
be used with AC or MFDC,
the WS2003 is really a
universal system.
Weld timer WS2003 |
 |
Features:
• Welding modes: Single
Spot , repeat, Roll-Spot
and Seam.
• Compatible with OHMA
guns
• Constant Current
• Up to 64 programs
• Network or Pendant can
be used for Programming
• Upslope or Downslope
• 14 inputs
• 12 outputs + pulse SCR
drive
• Outputs will drive 24v
DC or 110v AC loads
• Monitoring of current
Feedback
• Primary or via
secondary toroid.
• Toroid Function test
• Calibration Functions
for Toroidal and
proportional valve
• Weld History Log.
• Proportional valve
control (0-10v or
4-20mA)
• Pressure Monitoring
• End of sequence o / p
• Retraction (3 modes)
• Weld Counter,
programmable with lock
• Stepper Function with
programmable pre curves
adjustment and locks
• Programmable Logic
Sequencer
• Programmable Outputs
• Contactor Output
• Low Force approach
• Head Lock Function
• RS232 port for PC
connection
• Fieldbus control
optional extras
(Ethernet, Profibus,
DeviceNet, etc.) |
|
|
|
 |
|
Weld
parameters |
|
Monitoring
limits |
|
Counters |
Pre-squese
squese
weld 1
Cool 1
weld2
Cool 2
Pulses
Hold
Balance
Off
Pressure
Heat1
Heat 2
Current
1
Current
2 |
0 – 99
cycles
0 – 99
cycles
0 – 99
cycles
0 – 99
cycles
0 – 99
cycles
0 – 99
cycles
0 – 9
pulses
0 – 99
cycles
0 – 60%
(only
seam)
0 – 99
cycless
0 – 100%
0 – 99%
0 – 99%
0 – 60
kA
0 – 60
kA |
|
Current
monitor
Low
current
– weld 1
high
current
– weld1
Pre-limit
– weld 1
Low
current
– weld 2
high
current
– weld 2
Pre-limit
– weld 2
Count
pre-limit
Pressure
monitoring
Low
pressure
high
pressure
|
On/off
0 – 99%
0 – 99%
0 – 99%
0 – 99%
0 – 99%
0 – 99%
0 – 99
On/off
0 – 99%
0 – 99% |
|
Count
Count
now
Count at
|
0-9999
0-9999
stop at
end or
continue
at end |
| |
|
Events |
|
Additional
parameters
for OHMA
guns |
|
Electric |
|
4 x 4
spots at
fire
WS2003 |
|
open
OHMA
close
OHMA
open
with
retract
OHMA
Retract
with lag
OHMA
Retract
with
close
OHMA |
0 – 99
cycles
0 – 99
cycles
0 – 99
cycles
0 – 99
cycles
0 – 99
cycles |
|
24 v DC
500mA (all
o/ps
off)
24 v AC
50/60 Hz
synch. |
Inputs:
24v
DC<10mA
Outputs:
24v
DC<500mA
SCR
drive:
5kHz:
1:10
mark/space:
first
pulse
24;
subsequent
pulses >
15v |
|
|
|
|
|
|
|
| |
-
Weld timers LD 01 e LD 03
-
| |

 |
Microprocessor control
of welding up to 8
starts and 100 programs,
with 22 functions for
welding parameters.
Binary combination of up
to 20 starts and 10
starts with valve 1 and
10 starts at valve 2.
Available in vertical
version mod. LD-01 and
the horizontal version
mod. LD-03. |
|
|
|
|
| |
-
Weld timer LD 10
-
| |

 |
Microprocessor based
welding control LD-10 is
versatile, and easy to
use. Low cost
installation. with 2
starts, 2 output valves
and 10 programas. Parts
counter and spot with
input and output for
monitoring and blocking.
Excellent for